Part No. : AB2-B0-34-620-5D1-C | Alternate P/N : AB2B0346205D1C | Manufacturer : carling technologies inc |
Item Name: circuit breaker | NSN: 5925-01-591-4574 (5925015914574) | CAGE Code: 73559 |
FSC: 5925 Circuit Breakers |
If you require part number AB2-B0-34-620-5D1-C from Carling Technologies Inc which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number AB2-B0-34-620-5D1-C which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015914574 and was produced under the CAGE Code 73559. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part AB2-B0-34-620-5D1-C today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. AB2-B0-34-620-5D1-C
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-591-4574 Item Description: Circuit Breaker | 5925 | 015914574 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ab2-B0-34-620-5d1-C | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.130 NOMINAL INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.032 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 80.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADAT | Body Width | 1.515 INCHES NOMINAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE TWO |
TTQY | Terminal Type And Quantity | 4 SCREW |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 7500.0 DC ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.660 INCHES NOMINAL |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload