Part No. : W111D | Manufacturer : deltron inc | Item Name: powersupply |
NSN: 6130-01-317-4732 (6130013174732) | CAGE Code: 00417 | FSC: 6130 Converters Electrical Non Rotating |
If you require part number W111D from Deltron Inc which is described as a Powersupply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number W111D which is listed under the Federal Supply Class 6130 Converters Electrical Non Rotating. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130013174732 and was produced under the CAGE Code 00417. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part W111D today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. W111D
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-317-4732 Item Description: Powersupply | 6130 | 013174732 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
W111d | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 4.870 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.750 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 100.0 AC POUNDS PER HOUR WET 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 117.0 AC POUNDS PER HOUR WET 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR WET 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 240.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 3RD OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 4TH OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 4TH OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 5TH OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 5TH OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -0.1/+50.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 6.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
ABHP | OVERALL LENGTH | 9.000 INCHES NOMINAL |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload