Part No. : 6962ED2069A2 | Manufacturer : drs power and control technologies | Item Name: starter motor |
NSN: 6110-00-482-2726 (6110004822726) | CAGE Code: 27192 | FSC: 6110 Electrical Control Equipment |
If you require part number 6962ED2069A2 from Drs Power And Control Technologies which is described as a Starter Motor component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 6962ED2069A2 which is listed under the Federal Supply Class 6110 Electrical Control Equipment. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6110004822726 and was produced under the CAGE Code 27192. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 6962ED2069A2 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 6962ED2069A2
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6110-00-482-2726 Item Description: Starter Motor | 6110 | 004822726 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6962ed2069a2 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 16.100 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 20.120 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 9.500 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AFLW | ACTUATION METHOD | MAGNETIC |
AGLD | PERFORMANCE TYPE | SEMIAUTOMATIC |
AGUE | FUSE ACCOMMODATION QUANTITY | 2 |
AKPS | DUTY CYCLE | CONTINUOUS |
ALGC | MOUNTING CONFIGURATION | FOUR 17/32 IN. DIA MTG HOLES ON 18 IN. BY 12-1/2 IN. MTG CENTERS |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ANCY | HORSEPOWER RATING | 50.000 |
ANDE | ACTUATOR VOLTAGE | 440.0 AC |
ANDG | FUSE CURRENT RATING IN AMPS | 10.0 |
ANDW | LOAD PROTECTION TYPE | OVERLOAD |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | NOT DESIGNED PER NEMA STD |
ANRK | SWITCH FUNCTIONAL POSITIONS | AUTOMATIC AND MANUAL |
AQZF | CONTROL TYPE | LOCAL OR REMOTE |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
FAAZ | PHASE | THREE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.