Part No. : 1658-G21-02-S83-10A | Alternate P/N : 1658G2102S8310A | Manufacturer : e t a circuit breakers |
Item Name: circuit breaker | NSN: 5925-01-590-5326 (5925015905326) | CAGE Code: 3D8G0 |
FSC: 5925 Circuit Breakers |
If you require part number 1658-G21-02-S83-10A from E T A Circuit Breakers which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 1658-G21-02-S83-10A which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015905326 and was produced under the CAGE Code 3D8G0. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 1658-G21-02-S83-10A today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 1658-G21-02-S83-10A
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-590-5326 Item Description: CIRCUIT BREAKER | 5925 | 015905326 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1658-G21-02-S83-10A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 12.7 MILLIMETERS NOMINAL |
ADAQ | BODY LENGTH | 32.0 MILLIMETERS NOMINAL |
ADAT | BODY WIDTH | 14.0 MILLIMETERS NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 17.5 MILLIMETERS NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 39.0 MILLIMETERS NOMINAL |
AKPX | POLE QUANTITY | 1 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 200.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | -20.0 DEG CELSIUS MINIMUM SINGLE LOCATION AND 60.0 DEG CELSIUS MAXIMUM SINGLE LOCATION |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CAGE: THERMAL OVERCURRENT CIRCUIT BREAKER 1658 |
FEAT | SPECIAL FEATURES | SINGLE POLE THERMAL CB; MANUAL RESET TYPE, 3/8 INCH-27 THREADNECK; ONE PAL NUT, ONE KNURLED NUT, BULK; TWO 90 DEGREE BENT SCREW TERMINALS; 10AMPS |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.