| Part No. : GH3-G3-U-0060-03B | Alternate P/N : GH3G3U006003B | Manufacturer : eaton corporation |
| Item Name: circuitbreaker | NSN: 5925-01-552-5335 (5925015525335) | CAGE Code: 1W134 |
| FSC: 5925 Circuit Breakers |
If you require part number GH3-G3-U-0060-03B from Eaton Corporation which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number GH3-G3-U-0060-03B which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015525335 and was produced under the CAGE Code 1W134. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part GH3-G3-U-0060-03B today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-552-5335 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015525335 | P | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| GH3-G3-U-0060-03B | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.687 INCHES NOMINAL |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL |
| FEAT | SPECIAL FEATURES | OPERATING TEMPERATURE RANGE MINUS 40.0 TO PLUS 85.0 DEGREES C; VOLTAGE RATING 251.0 TO 600.0 VOLTS AC |
| AKPX | POLE QUANTITY | 3 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 14000.0 AC ALL LOCATIONS |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABTD | MOUNTING SLOT WIDTH | 0.203 INCHES NOMINAL |
| ADAT | BODY WIDTH | 4.125 INCHES NOMINAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60.0 AMPERES AC ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
| AJEC | BOSS HEIGHT | 0.250 INCHES NOMINAL |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.000 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| ADAU | BODY HEIGHT | 3.125 INCHES NOMINAL |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS |
| ADTV | CASE MATERIAL | PLASTIC |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.375 INCHES NOMINAL |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.