| Part No. : FA5009-3E | Alternate P/N : FA50093E | Manufacturer : filtron co inc |
| Item Name: filter radio frequency interfere | NSN: 5915-00-104-1403 (5915001041403) | CAGE Code: 81831 |
| FSC: 5915 Filters and Networks |
If you require part number FA5009-3E from Filtron Co Inc which is described as a Filter Radio Frequency Interfere component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number FA5009-3E which is listed under the Federal Supply Class 5915 Filters and Networks. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5915001041403 and was produced under the CAGE Code 81831. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part FA5009-3E today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5915-00-104-1403 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 001041403 | 0 | Y | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| FA5009-3E | 6 | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 BLANK |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC BLANK |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
| AKNA | INCLOSURE TYPE | ENCASED |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK |
| CQRG | BODY MATERIAL | METAL |