| Part No. : 55-1330039-1 | Alternate P/N : 5513300391 | Manufacturer : general dynamics mission systems |
| Item Name: transformer power | NSN: 5950-01-357-7075 (5950013577075) | CAGE Code: 04655 |
| FSC: 5950 Coils and Transformers |
If you require part number 55-1330039-1 from General Dynamics Mission Systems which is described as a Transformer Power component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 55-1330039-1 which is listed under the Federal Supply Class 5950 Coils and Transformers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5950013577075 and was produced under the CAGE Code 04655. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 55-1330039-1 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-357-7075 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013577075 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 05110 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.690 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ADAU | BODY HEIGHT | 3.937 INCHES NOMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | 60.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| CWJS | WINDING OPERATING VOLTAGE | 38.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 11 STANDOFF,THREADED STUD |
| ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 435.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| ADAQ | BODY LENGTH | 4.627 INCHES NOMINAL |
| ADAT | BODY WIDTH | 4.846 INCHES NOMINAL |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |