Part No. : AM3R-A38-LC07T-NU-20-7 | Alternate P/N : AM3RA38LC07TNU207 | Manufacturer : heinemann electric co inc |
Item Name: circuit breaker | NSN: 5925-01-552-2630 (5925015522630) | CAGE Code: L3330 |
FSC: 5925 Circuit Breakers |
If you require part number AM3R-A38-LC07T-NU-20-7 from Heinemann Electric Co Inc which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number AM3R-A38-LC07T-NU-20-7 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015522630 and was produced under the CAGE Code L3330. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part AM3R-A38-LC07T-NU-20-7 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. AM3R-A38-LC07T-NU-20-7
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-552-2630 Item Description: CIRCUIT BREAKER | 5925 | 015522630 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM3R-A38-LC07T-NU-20-7 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND VIBRATION RESISTANT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CTTC | Thread Tolerance Class | 2B INTERNAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 2.250 INCHES NOMINAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 2.860 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
FEAT | Special Features | OPERATING TEMPERATURE MINUS 40.0 TO PLUS 85.0 DEGREES C. |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CMLP | Thread Quantity Per Inch | 32 |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
CPRW | Actuator Function | TRIP-RESET |