| Part No. : PCX40-0-5C | Alternate P/N : PCX4005C | Manufacturer : kepco inc |
| Item Name: power supply | NSN: 6130-00-162-7487 (6130001627487) | CAGE Code: 85604 |
If you require part number PCX40-0-5C from Kepco Inc which is described as a Power Supply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number PCX40-0-5C which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130001627487 and was produced under the CAGE Code 85604. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part PCX40-0-5C today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-00-162-7487 Item PartTypeName: POWER SUPPLY | 6130 | 001627487 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| PCX40-0-5C | 5 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 16.906 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 2.688 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 4.219 INCHES NOMINAL |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
| ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 105.0 DC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 125.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 40.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
| APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
| AYNH | OPERATING AMBIENT TEMP RANGE | -20.0 TO 65.0 DEG CELSIUS |
| BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
| BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
| BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
| CBBL | FEATURES PROVIDED | EMI FILTER |
| CWGH | OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,PLUG SINGLE POWER OUTPUT |
| CWKG | VENTILATION DESIGN TYPE | AMBIENT AIR |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.