| Part No. : 04761 | Manufacturer : magnetika inc | Item Name: transformer power |
| NSN: 5950-01-294-4998 (5950012944998) | CAGE Code: 15634 |
If you require part number 04761 from Magnetika Inc which is described as a Transformer Power component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 04761 which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5950012944998 and was produced under the CAGE Code 15634. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 04761 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-294-4998 Item PartTypeName: TRANSFORMER,POWER | 5950 | 012944998 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 04761 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 5.620 INCHES NOMINAL |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 4.120 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 3.920 INCHES NOMINAL |
| ABTB | MOUNTING HOLE DIAMETER | 0.339 INCHES MINIMUM AND 0.350 INCHES MAXIMUM 1ST GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 20.0 MEGAHERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.125 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
| AKPV | MOUNTING FACILITY QUANTITY | 6 1ST GROUP |
| AXGY | MOUNTING METHOD | BRACKET 2ND GROUP |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE 1ST GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES 2ND GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 84.00 AC VOLTS MINIMUM AND 132.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| FEAT | SPECIAL FEATURES | CRITICAL APPLICATION ITEM CAI) |
| THSD | THREAD SERIES DESIGNATOR | UNC 2ND GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD AND 2 TAB,SOLDER LUG |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.