Part No. : 122A10-00M | Alternate P/N : 122A1000M | Manufacturer : mcgraw edison co |
Item Name: circuitbreaker | NSN: 5925-01-503-4543 (5925015034543) | CAGE Code: 11873 |
FSC: 5925 Circuit Breakers |
If you require part number 122A10-00M from Mcgraw Edison Co which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 122A10-00M which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015034543 and was produced under the CAGE Code 11873. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 122A10-00M today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 122A10-00M
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-503-4543 Item Description: Circuitbreaker | 5925 | 015034543 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
122a10-00m | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 400.0 SINGLE LOCATION |
FEAT | SPECIAL FEATURES | TERMINALS - TWO 10-32 STUDS; NO BRACKET; LENGTH 1.240 INCHES, WIDTH 0.790 INCHES, HEIGHT 0.640 INCHES; OPERATING TEMPERATURE - MINUS 10 DEGREES F TO 150 DEGREES F |
AKPX | POLE QUANTITY | 1 |
AGAV | III END ITEM IDENTIFICATION | NSN2320-01-432-4847; WEAPON SYSTEM - TRUCK, M-915 SERIES, M-916A1(LET) |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES DC SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 12.0 DC SINGLE LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 3.500 NOMINAL SINGLE LOCATION |
ADTV | CASE MATERIAL | METAL |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3.500 NOMINAL AT 400 PCT SINGLE LOCATION |