Item Name: circuit breaker | NSN: 5925-01-591-6121 (5925015916121) | CAGE Code: 76526 |
FSC: 5925 Circuit Breakers |
If you require part number FAZ-D10 2-NA from Moeller Instrument Company Inc which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number FAZ-D10 2-NA which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015916121 and was produced under the CAGE Code 76526. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part FAZ-D10 2-NA today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. FAZ-D10 2-NA
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 105.0 MILLIMETERS NOMINAL |
ADAT | BODY WIDTH | 35.4 MILLIMETERS NOMINAL |
ADAU | BODY HEIGHT | 44.0 MILLIMETERS NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 17.7 MILLIMETERS NOMINAL |
AGAV | END ITEM IDENTIFICATION | AIRCRAFT C295 |
AJEC | BOSS HEIGHT | 16.0 MILLIMETERS NOMINAL |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | DIN RAIL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 277.0 AC ALL LOCATIONS AND 480.0 AC ALL LOCATIONS AND 96.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS AND 10000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 1000.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE AND AT POLE TWO |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 AT 800 PCT PASCAL ALL LOCATIONS AND 90.000 18 STAGE PASCAL ALL LOCATIONS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | FAZ NA MINIATURE BRANCH CIRCUIT BREAKER FOR HIGHLY INDUCTIVE LOAD |
FEAT | SPECIAL FEATURES | SUITABLE FOR APPLICATIONS WHERE HIGH LEVELS OF INRUSH CURRENT ARE EXPECTED; PREVENTS NUISANCE TRIPPING IN HIGH INDUCTIVE APPS |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SCREW |