Part No. : 414-00005-08 | Alternate P/N : 4140000508 | Manufacturer : oeco corp |
Item Name: circuitbreaker | NSN: 5925-01-322-2046 (5925013222046) | CAGE Code: 95266 |
FSC: 5925 Circuit Breakers |
If you require part number 414-00005-08 from Oeco Corp which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 414-00005-08 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925013222046 and was produced under the CAGE Code 95266. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 414-00005-08 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 414-00005-08
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-322-2046 Item Description: Circuitbreaker | 5925 | 013222046 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
414-00005-08 | 5 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AAJE | THREAD PITCH DIAMETERS | +0.1177/+0.1214 INCHES |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.515 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CQJX | NOMINAL THREAD SIZE | 0.134 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
ZZZK | SPECIFICATION/STANDARD DATA | 95266-414-00005-08 MANUFACTURERS SOURCE CONTROL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC SECOND LOCATION |
CPRQ | RESET METHOD | MANUAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.444 INCHES MINIMUM AND 2.506 INCHES MAXIMUM |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.920 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
AJEC | BOSS HEIGHT | 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES DC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC FIRST LOCATION |
CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 25.0 DC NOMINAL ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.180 MINIMUM AT 200 PCT SECOND LOCATION AND 1.800 MAXIMUM AT 200 PCT SECOND LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.700 MINIMUM AT 200 PCT FIRST LOCATION AND 10.000 MAXIMUM AT 200 PCT FIRST LOCATION |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.